BGRFM - SKD-NF/ZP-9B DEVELOPER (OLD FORMULATION)
- MSDS: BGRFM
- Manufacturer: MAGNAFLUX CORP
- Product Name: SKD-NF/ZP-9B DEVELOPER (OLD FORMULATION)
- National Stock Number: 6850-01-241-0651
Product Identification
Product ID:SKD-NF/ZP-9B DEVELOPER (OLD FORMULATION)
MSDS Date:08/19/1988
FSC:6850
NIIN:01-241-0651
MSDS Number: BGRFM
Responsible Party
CHICAGO, IL 60656-3504
US
Emergency Phone: 708-867-8000
Info Phone: 708-867-8000
Preparer: BRUCE C. GRAHAM
Cage: 37676
Contractor
Telephone: 847-657-5300/
Cage: 37676
Ingredients
METHYL CHLOROFORM (1,1,1-TRICHLOROEHANE) (SARA III)
CAS: 71-55-6
RTECS: KJ2975000
Fraction By Weight: 65.0%
OSHA PEL 350 PPM/450 STEL
ACGIH TLV: 350 PPM/450STEL;9192
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
CHLORODIFLUOROMETHANE
CAS: 75-45-6
RTECS: PA6390000
Fraction By Weight: 25.0%
OSHA PEL 1000 PPM
ACGIH TLV: 1000PPM; 9192
1,4-DIOXANE (DIETHYLENE DIOXIDE) (SARA III)
CAS: 123-91-1
RTECS: JG8225000
Fraction By Weight: 02.0%
OSHA PEL S, 100 PPM
ACGIH TLV: S, 25 PPM; 9293
EPA Report Quantity: 100 LBS
DOT Report Quantity: 100 LBS
Hazards
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:IRRITATES EYES BY SOLVENT
ACTION;EXPOSURE ABOVE TLV LIMITS CAN RESULT IN CLUMSNESS AND POOR
JUDGEMENT,WITH RESULTING DANGER TO THE VICTIM.DUE TO LACK OF OXYGEN
&/OR SUFFOCATION,DEATH CAN OCCUR.
Explanation of Carcinogenicity:1,1,1-TRICHLOROETHANE AND 1,4-DIOXANE
ARE CURRENTLY UNDER TEST TO DETERMINE THE POSSIBLE
CARCINOGENICITY,PER MFR.
Effects of Overexposure:INHALATION:CAUSES
DIZZINESS,DROWSINESS,NAUSEA.CAUSES UNCONSCIOUSNESS AT HIGH
EXPOSURE; SKIN:NOT ABSORBED THROUGH SKIN IN SIGNIFICANT
AMOUNTS.HOWEVER,IRRITATES BY DISSOLVING SKIN OILS; EYES:IRRITATING
DUE TO STRONG SOLVENT ACTION; INGESTION:LOW SINGLE DOSE TOXICITY IN
TEST ANIMALS.
Medical Cond Aggravated by Exposure:NONE KNOWN TO MANUFACTURER.
First Aid
First Aid:INHALATION:REMOVE TO FRESH AIR.IF NOT BREATHING,GIVE CPR.IF
BREATHING IS DIFFICULT,GIVE OXYGEN; SKIN:WASH OFF IN FLOWING WATER
OR SHOWER.RMV CONTAMINATED CLOTHING AND WASH BEFORE RE-USE.USE
SOOTHING L OTION; EYES:FLUSH EYES WITH A STEADY,GENTLE FLOW OF
WATER.GET MEDICAL ASST; INGESTION:DO NOT INDUCE VOMITING.IF VOMIT
IS INHALED,IT MAY CAUSE ASPHYIATION.GET MED ATTN IMMEDIATELY;IN
EMERGENCY CALL MD
Fire Fighting
Flash Point:NONE
Lower Limits:10%
Upper Limits:15%
Extinguishing Media:CARBON DIOXIDE,FOAM.
Fire Fighting Procedures:KEEP CONTAINERS COOL WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:AEROSOL CANS CAN BURST IF HEATED ABOVE
130F(54.4C).
Accidental Release
Spill Release Procedures:LESS THAN ONE QUART:WIPE UP BUT DO NOT BREATHE
VAPORS;ONE QUART OR MORE:WEAR ALL PERSONAL SAFETY EQUIPMENT TO
AVOID VAPOR/LIQ CONTACT OR BREATHING.EVACUATE UNPROTECTED
PERSONS.ELIMINATE IGN SOURCES.DI KE LIQ.PLACE IN COVERED DRUMS.SEND
TO RECLAIMER.
Neutralizing Agent:NOT NOTED BY MFR.
Handling
Handling and Storage Precautions:STORE AWAY FROM HEAT SOURCES TO
MINIMIZE THE DANGER FROM EXPOSURE TO FIRES.STORE IN
DRY,COOL,VENTILATED AREA.
Other Precautions:DO NOT USE AROUND FLAMES/RED HOT SURFACES.DO NOT HEAT
ABOVE 130F.AVOID BREATHING VAPORS.AVOID FREQUENT/PROLONGED EXPOSURE
TO SKIN.
Exposure Controls
Respiratory Protection:WEAR RESPIRATOR WITH CHEMICAL CARTRIDGE.IN
CONFINED AREAS,WEAR A FULL MASK WITH SEPARATE AIR SUPPLY.
Ventilation:GENERAL VENTILATION TO KEEP BELOW 350PPM OF TLV LIMIT.
Protective Gloves:NITRILE RUBBER GLOVES.
Eye Protection:FULL GOGGLES.
Other Protective Equipment:USE IN SPRAY BOOTH OR NEXT TO AN EXHAUST
VENT TO CARRY VAPORS AWAY FROM OCCUPIED AREAS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING MATERIAL.LAUNDER
CONTAMINATED CLOTHES BEFORE REUSE SKD-NF/ZP-9B DEVELOPER.
Supplemental Safety and Health
SOLE SOURCE/NON-STANDARD NSN FOR MAGNAFLUX P/N:SKD-NF/ZP-9B
DEVELOPER.TECHNICAL SERVICES MAY CANCEL/UPDATE THIS NSN ON LATER
DATE.
Chemical Properties
HCC:V2
Spec Gravity:1.3 (OF LIQUID)
Evaporation Rate & Reference:0.7 (ETHER=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:THIN,WHITE LIQUID BEFORE FILLING IN AEROSOL CANS.
Percent Volatiles by Volume:100%
Stability
Stability Indicator/Materials to Avoid:YES
ALKALI METALS.
Stability Condition to Avoid:HEAT/HIGH TEMPERATURES.
Hazardous Decomposition Products:PHOSGENE,HYDROCHLORIC ACID GAS,&
OXIDES OF CARBON.
Disposal
Waste Disposal Methods:DISPOSE OF AS EPA HAZARDOUS WASTE #F002; MAY BE
SENT TO SOLVENT RECLAIMER.INSURE THAT AEROSOL CANS ARE EMPTY AND
DEPRESSURIZED BEFORE DISCARDING,UNLESS A WASTE TREATMENT FACILITY
IS APPROVED TO ACCEPT THEM AS IS.COMPLY WITH FED,ST& LOCAL REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.